{"product_id":"elektrokessel-attack-elctric-exellent-8-kw","title":"Electric boiler ATTACK Electric Exellent 8 kW central heating and hot water","description":"\u003ch2 data-end=\"60\" data-start=\"0\"\u003eATTACK Electric Excellent 8 kW (nominal heat output 7.5 kW)\u003c\/h2\u003e\n\u003ch3 data-end=\"489\" data-start=\"62\"\u003e\u003cstrong data-end=\"86\" data-start=\"62\"\u003eProduct description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"489\" data-start=\"62\"\u003eThe ATTACK Electric Excellent 8 is a wall-mounted electric boiler for heating systems with forced circulation. The PID controller activates heating stages as needed and ensures stable temperatures. Optional control via room thermostat and GSM\/smartphone is possible. Hot water can be provided via an external storage tank in conjunction with a 3-way valve (TUV operation).\u003c\/p\u003e\n\u003ch3 data-end=\"506\" data-start=\"491\"\u003e\u003cstrong data-end=\"506\" data-start=\"491\"\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"695\" data-start=\"507\"\u003e\n\u003cli data-end=\"568\" data-start=\"507\"\u003e\n\u003cp data-end=\"568\" data-start=\"509\"\u003e99% efficiency, quiet operation, LCD display with diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"640\" data-start=\"569\"\u003e\n\u003cp data-end=\"640\" data-start=\"571\"\u003eProtective functions (including frost, overheating and pressure loss protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"695\" data-start=\"641\"\u003e\n\u003cp data-end=\"695\" data-start=\"643\"\u003eSuitable for radiator and underfloor heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1009\" data-start=\"697\"\u003e\u003cstrong data-end=\"718\" data-start=\"697\"\u003eAreas of application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 data-end=\"1009\" data-start=\"697\"\u003e\u003cstrong data-end=\"738\" data-start=\"721\"\u003eSuitable for:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"1009\" data-start=\"697\"\u003eApartments and single-family homes,\u003c\/li\u003e\n\u003cli data-end=\"1009\" data-start=\"697\"\u003esmall heating circuits up to 7.5 kW heat load,\u003c\/li\u003e\n\u003cli data-end=\"1009\" data-start=\"697\"\u003emodernization without flue gas routing,\u003c\/li\u003e\n\u003cli data-end=\"1009\" data-start=\"697\"\u003esupplementary\/backup heating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"1009\" data-start=\"697\"\u003e\n\u003cbr data-end=\"871\" data-start=\"868\"\u003e\u003cstrong data-end=\"894\" data-start=\"871\"\u003eNot suitable for:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"1009\" data-start=\"697\"\u003esystems without a circulation pump (gravity),\u003c\/li\u003e\n\u003cli data-end=\"1009\" data-start=\"697\"\u003eheat demand above 7.5 kW,\u003c\/li\u003e\n\u003cli data-end=\"1009\" data-start=\"697\"\u003edomestic hot water preparation without a storage tank\/TUV module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1056\" data-start=\"1011\"\u003e\u003cstrong data-end=\"1056\" data-start=\"1011\"\u003eTechnical data (including explanation):\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1693\" data-start=\"1057\"\u003e\n\u003cli data-end=\"1118\" data-start=\"1057\"\u003e\n\u003cp data-end=\"1118\" data-start=\"1059\"\u003e\u003cstrong data-end=\"1072\" data-start=\"1059\"\u003eOutput:\u003c\/strong\u003e 7.5 kW (heat output; model designation \u0026quot;8\u0026quot;)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1204\" data-start=\"1119\"\u003e\n\u003cp data-end=\"1204\" data-start=\"1121\"\u003e\u003cstrong data-end=\"1134\" data-start=\"1121\"\u003eVoltage:\u003c\/strong\u003e 1×230 V or 3×230\/400 V (flexible connection depending on installation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1321\" data-start=\"1205\"\u003e\n\u003cp data-end=\"1321\" data-start=\"1207\"\u003e\u003cstrong data-end=\"1235\" data-start=\"1207\"\u003eRated current \/ fuse protection:\u003c\/strong\u003e 1×36 A \/ 3×12 A; \u003cstrong data-end=\"1271\" data-start=\"1253\"\u003eMain switch:\u003c\/strong\u003e 1×40 A \/ 3×16 A (relevant for electrical design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1386\" data-start=\"1322\"\u003e\n\u003cp data-end=\"1386\" data-start=\"1324\"\u003e\u003cstrong data-end=\"1338\" data-start=\"1324\"\u003eProtection class:\u003c\/strong\u003e IP40 (enclosure protection in dry indoor areas)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1429\" data-start=\"1387\"\u003e\n\u003cp data-end=\"1429\" data-start=\"1389\"\u003e\u003cstrong data-end=\"1425\" data-start=\"1389\"\u003eEnergy efficiency class (heating):\u003c\/strong\u003e D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1510\" data-start=\"1430\"\u003e\n\u003cp data-end=\"1510\" data-start=\"1432\"\u003e\u003cstrong data-end=\"1450\" data-start=\"1432\"\u003eOperating pressure:\u003c\/strong\u003e 0.4–3 bar; \u003cstrong data-end=\"1482\" data-start=\"1462\"\u003emax. temperature:\u003c\/strong\u003e 80 °C (system safety)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1590\" data-start=\"1511\"\u003e\n\u003cp data-end=\"1590\" data-start=\"1513\"\u003e\u003cstrong data-end=\"1530\" data-start=\"1513\"\u003eWater content:\u003c\/strong\u003e 10.6 l; \u003cstrong data-end=\"1560\" data-start=\"1539\"\u003eExpansion vessel:\u003c\/strong\u003e 8 l (system volume\/reserve)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1634\" data-start=\"1591\"\u003e\n\u003cp data-end=\"1634\" data-start=\"1593\"\u003e\u003cstrong data-end=\"1622\" data-start=\"1593\"\u003eFlow\/return connections:\u003c\/strong\u003e G 3\/4\u0026quot; male thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1693\" data-start=\"1635\"\u003e\n\u003cp data-end=\"1693\" data-start=\"1637\"\u003e\u003cstrong data-end=\"1654\" data-start=\"1637\"\u003eDimensions (H×W×D):\u003c\/strong\u003e 656×450×345 mm; \u003cstrong data-end=\"1683\" data-start=\"1671\"\u003eWeight:\u003c\/strong\u003e 36.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1902\" data-start=\"1695\"\u003e\u003cstrong data-end=\"1712\" data-start=\"1695\"\u003eScope of delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1902\" data-start=\"1695\"\u003eBoiler (assembled), operating instructions, warranty card, socket, vent valve, bridge\/connection for 1×230 V. Not included: mounting kit, TUV module, GSM module, connection cables.\u003c\/p\u003e\n\u003ch3 data-end=\"2072\" data-start=\"1904\"\u003e\u003cstrong data-end=\"1914\" data-start=\"1904\"\u003eConclusion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2072\" data-start=\"1904\"\u003eCompact electric boiler for small heating loads – precisely controlled, safely equipped and ideal for clean heating modernizations without flue gas routing.\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Vaiketitel","offer_id":54837360001372,"sku":"AEK8EX","price":1080.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/elektrokessel-attack-electric-exellent-8-kw-zentralheizung-u-warmwasser-7001816.png?v=1770692133","url":"https:\/\/ee.gemashop.de\/en\/products\/elektrikatel-attack-elctric-exellent-8-kw","provider":"GEMA Shop","version":"1.0","type":"link"}