{"product_id":"elektroheizstab-mit-regler-und-thermostat-9-0-kw","title":"Electric heating element SELFA ZGTi 9.0 kW","description":"\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e\n\u003cp\u003eThe SELFA ZGTi 9.0 kW electric heating element is an electric screw-in heater for direct water heating in suitable hot water, drinking water, and buffer tanks. It is suitable as an auxiliary heater, reheater, or temporary electric heat source when the tank connection, tank content, installation length, water quality, and electrical connection conditions match the 9.0 kW version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e\n\u003cp\u003eThe ZGTi version features integrated temperature control, a safety temperature limiter, and galvanically isolated heating elements. The desired water temperature is regulated via the adjustment knob on the connection head. The indicator lights on the housing show the power supply and heating operation, so the operating status is directly visible on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eEveryday Benefits\u003c\/h2\u003e\n\u003cp\u003eThe heating element enables thermostat-controlled electric reheating directly in the tank. Once the set temperature is reached, the thermostat switches off the heating elements and automatically switches them back on when the temperature drops. The 9.0 kW version is intended for tank systems where a correspondingly higher electric auxiliary output is required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe SELFA ZGTi 9.0 kW is intended for tanks with a suitable 1 1\/2-inch connection socket. Before installation, the installation length, minimum tank volume, operating pressure, water quality, connection position, and electrical connection conditions must be professionally checked. The heating element may only be operated in water-filled tanks and must remain permanently and sufficiently covered with water during operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e\n\u003cdiv class=\"product-th\"\u003e\n\u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e\n\u003cp\u003eThe following technical data refers to the DEFRO ZGTi 9.0 kW performance variant.\u003c\/p\u003e\n\u003ctable class=\"product-th__table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRated output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e9.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e9000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003ethree-phase \/ 3 x 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eConnection type\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5-wire, 1.5 mm², without plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eConnection size\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1 1\/2 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. temperature control\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eAISI 316L pipe material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMinimum storage volume\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e250 liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eThe heating element is screwed into a suitable 1 1\/2-inch connection socket of the storage tank. Before commissioning, the storage tank, connection socket, sealing surface, installation position, tightness and water filling must be checked. A sufficient distance from the tank walls and internal components must be maintained inside the storage tank. Mechanical installation, electrical connection and functional testing may only be carried out by qualified specialists.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cp\u003eThe heating element must not be operated dry. With hard water, regular visual inspection and descaling are important, as limescale deposits can impair heat transfer and lead to overheating. After the safety temperature limiter has tripped, the device may only be put back into operation after it has cooled down, the circuit has been de-energized and the cause has been professionally investigated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gema-section\"\u003e\n\u003ch2\u003eScope of delivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSELFA ZGTi screw-in heating element 9.0 kW with integrated controller and thermostat\u003c\/li\u003e\n\u003cli\u003eFive-core connection cable without plug\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"SELFA","offers":[{"title":"Vaiketitel","offer_id":47926366110044,"sku":"DEH39","price":281.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/elektroheizstab-mit-regler-und-thermostat-90-kw-4176600.jpg?v=1770692657","url":"https:\/\/ee.gemashop.de\/en\/products\/elektroheizstab-koos-regulaatori-ja-termostaadiga-9-0-kw","provider":"GEMA Shop","version":"1.0","type":"link"}