{"product_id":"gema-mdc-400-bundle-modul-heizstab-tehp6-6-0-kw-400-v","title":"GEMA MDC 400 heating module + heating element TEHP6 6.0 kW 400 V","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC 400 Bundle Module Heating Element TEHP6 combines an MDC 400 heating module with a matching 6.0 kW electric heating element for 400 V. The bundle is intended for electric supplementary heating in central heating systems and supports existing heat generators in the heating circuit.\u003c\/p\u003e \u003cp\u003eThe MDC module is used as a hydraulically integrated heating module, while the TEHP6 heating element provides the electric heat output. This makes the set suitable for reheating, frost protection support, emergency heat support, and the additional use of surplus electricity when the system is planned and integrated accordingly.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe MDC 400 heating module is designed for central heating systems and features a steel tank with 50 mm polyurethane foam insulation. The connection to the heating circuit is made via female thread G 1 1\/4\u0026quot;, and the connection for the electric heating cartridge is via female thread G 1 1\/2\u0026quot;.\u003c\/p\u003e \u003cp\u003eThe TEHP6 heating element corresponds to the 6.0 kW version of the WPI series. It operates at 400 V, has a sheath material of Incoloy 825, an IP54 protection rating, a temperature controller in the range of approx. 30 to 75 °C, and a safety temperature limiter at approx. 98 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe bundle creates a clearly assignable combination of heating module and matching electric heating cartridge. Operators thus receive an electric supplementary heat source that can support existing heating systems during temporary heat demand or as an additional heat source.\u003c\/p\u003e \u003cp\u003eThis solution is particularly helpful where an existing heat generator is to be supplemented without completely changing the basic structure of the heating system. The clear separation between module and heating element also facilitates technical assessment, spare part allocation, and later maintenance.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe MDC 400 module is intended for open or closed central heating systems with appropriate safety devices. Water or a suitable glycol mixture up to a maximum concentration of 50% is permitted as the medium.\u003c\/p\u003e \u003cp\u003eIntegration takes place in a parallel heating circuit on the flow or return of the main heat source. For the 6.0 kW version, a minimum flow rate of 343 l\/h or approx. 5.72 l\/min must be ensured. An additional circulation pump and a suitable safety valve must be taken into account when planning the system.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the specific bundle consisting of the MDC module and the matching electric heating cartridge.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBase module in the bundle\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMDC 400\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating element SKU in the bundle\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eTEHP6 \/ WPI-6.0\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated power\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e6.0 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e6,000 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003ethree-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eDirect control, three-phase star connection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating element connection size\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eG 1 1\/2\u0026quot; \/ 6\/4\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eImmersion heater installation length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e560 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eUnheated zone\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 120 mm from sealing surface\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eImmersion heater temperature range\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 30 to 75 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety temperature limiter\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 98 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eImmersion heater protection rating\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eIP54\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating element material\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eIncoloy 825\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMinimum flow rate\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e343 l\/h, approx. 5.72 l\/min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModule connection heating circuit\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/4\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/2\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. module operating temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eLength MDC 400\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e600 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMedium\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWater or suitable glycol mixture up to max. 50%\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe hydraulic integration of the MDC module must be carried out professionally into the heating circuit. Before switching on, the system and module must be completely filled and vented. The required minimum flow rate must be ensured via an additional circulation pump.\u003c\/p\u003e \u003cp\u003eThe electrical connection of the TEHP6 heating element may only be carried out by qualified electricians. The power supply may only be activated after the system has been filled, vented, and professionally inspected.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eDry running is not permitted and can cause damage to the heating element. The housing of the heating cartridge must not be covered or thermally insulated. A suitable safety valve with an opening pressure of 1.0 MPa is required.\u003c\/p\u003e \u003cp\u003eThe bundle does not replace proper system planning, heat load assessment, or electrical sizing. The design of fusing, wiring, safety devices, and hydraulic integration must match the specific system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eMDC 400 heating module\u003c\/li\u003e \u003cli\u003eTEHP6 \/ WPI-6.0 electric heating element 6.0 kW, 400 V\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Vaiketitel","offer_id":58079396364636,"sku":"MDC400+TEHP6","price":322.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/durchlauferhitzer-notheizung-mdc-400p-inkl-elektroheizstab-9-kw-4897799.webp?v=1770692302","url":"https:\/\/ee.gemashop.de\/en\/products\/gema-mdc-400-bundle-module-heating-element-tehp6-6-0-kw-400-v","provider":"GEMA Shop","version":"1.0","type":"link"}