{"product_id":"mpm-caldo-s-i-18-kw-holzvergaserkessel","title":"MPM Caldo S-I 18 kW wood gasification boiler for log wood","description":"\u003cp data-start=\"694\" data-end=\"1035\"\u003eThe \u003cstrong data-start=\"698\" data-end=\"718\"\u003eMPM Caldo S-I 18\u003c\/strong\u003e is a modern \u003cstrong data-start=\"736\" data-end=\"786\"\u003ewood gasification boiler with 18 kW nominal heat output\u003c\/strong\u003e for the efficient heating of residential buildings. The boiler is designed for operation with \u003cstrong data-start=\"869\" data-end=\"883\"\u003elog wood\u003c\/strong\u003e , meets the \u003cstrong data-start=\"907\" data-end=\"934\"\u003eEcodesign requirements\u003c\/strong\u003e and achieves the \u003cstrong data-start=\"952\" data-end=\"981\"\u003eenergy efficiency class A+\u003c\/strong\u003e. Operation requires \u003cstrong data-start=\"1003\" data-end=\"1034\"\u003ea buffer tank\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1037\" data-end=\"1040\"\u003e\n\u003ch2 data-start=\"1042\" data-end=\"1068\"\u003eHighlights \/ Benefits\u003c\/h2\u003e\n\u003cp data-start=\"1070\" data-end=\"1494\"\u003e⭐ \u003cstrong data-start=\"1072\" data-end=\"1100\"\u003eEfficient wood gasification\u003c\/strong\u003e – High efficiency with clean combustion\u003cbr data-start=\"1146\" data-end=\"1149\"\u003e⭐ \u003cstrong data-start=\"1151\" data-end=\"1184\"\u003eEcodesign \u0026 Class 5 compliant\u003c\/strong\u003e – Meets EU requirements according to Regulation (EU) 2015\/1189\u003cbr data-start=\"1238\" data-end=\"1241\"\u003e⭐ \u003cstrong data-start=\"1243\" data-end=\"1265\"\u003e18 kW heat output\u003c\/strong\u003e – Suitable for single-family homes and smaller commercial properties\u003cbr data-start=\"1326\" data-end=\"1329\"\u003e⭐ \u003cstrong data-start=\"1331\" data-end=\"1370\"\u003eManual loading with log wood\u003c\/strong\u003e – Independent of fossil fuels\u003cbr data-start=\"1405\" data-end=\"1408\"\u003e⭐ \u003cstrong data-start=\"1410\" data-end=\"1447\"\u003eMandatory operation with buffer tank\u003c\/strong\u003e – Optimal efficiency and longer service life\u003c\/p\u003e\n\u003chr data-start=\"1496\" data-end=\"1499\"\u003e\n\u003ch2 data-start=\"1501\" data-end=\"1531\"\u003eDetailed description\u003c\/h2\u003e\n\u003ch3 data-start=\"1533\" data-end=\"1566\"\u003eArea of application \u0026 target group\u003c\/h3\u003e\n\u003cp data-start=\"1567\" data-end=\"1874\"\u003eThe MPM Caldo S-I 18 is suitable for \u003cstrong data-start=\"1604\" data-end=\"1690\"\u003esingle-family homes, multi-family homes as well as smaller commercial and workshop buildings\u003c\/strong\u003e. It is intended for operation in open or closed heating systems and can also be used for domestic hot water preparation in conjunction with a suitable heat exchanger.\u003c\/p\u003e\n\u003ch3 data-start=\"1876\" data-end=\"1900\"\u003eEveryday benefits\u003c\/h3\u003e\n\u003cp data-start=\"1901\" data-end=\"2155\"\u003eThanks to the wood gasification technology, the fuel is used particularly efficiently. In combination with a buffer tank, you can achieve \u003cstrong data-start=\"2037\" data-end=\"2062\"\u003elong burn intervals\u003c\/strong\u003e, a \u003cstrong data-start=\"2068\" data-end=\"2097\"\u003euniform heating operation\u003c\/strong\u003e and a \u003cstrong data-start=\"2107\" data-end=\"2145\"\u003ereduction in fuel consumption\u003c\/strong\u003e .\u003c\/p\u003e\n\u003ch3 data-start=\"2157\" data-end=\"2184\"\u003eTechnology \u0026 equipment\u003c\/h3\u003e\n\u003cp data-start=\"2185\" data-end=\"2484\"\u003eThe boiler is made of \u003cstrong data-start=\"2204\" data-end=\"2243\"\u003ecertified boiler steel (P265GH)\u003c\/strong\u003e and features a \u003cstrong data-start=\"2276\" data-end=\"2302\"\u003etwo-chamber design\u003c\/strong\u003e with separate gasification and combustion chambers. The primary and secondary air supply is manually adjustable. A \u003cstrong data-start=\"2427\" data-end=\"2471\"\u003ethermal safety drain (cooling coil)\u003c\/strong\u003e is prepared as standard.\u003c\/p\u003e\n\u003ch3 data-start=\"2486\" data-end=\"2510\"\u003eEfficiency \u0026 environment\u003c\/h3\u003e\n\u003cp data-start=\"2511\" data-end=\"2735\"\u003eWith a \u003cstrong data-start=\"2521\" data-end=\"2561\"\u003eseasonal energy efficiency of 80%\u003c\/strong\u003e and the \u003cstrong data-start=\"2570\" data-end=\"2599\"\u003eenergy efficiency class A+\u003c\/strong\u003e , the boiler meets the current Ecodesign requirements. The emission values are within the permissible limits according to the EU regulation.\u003c\/p\u003e\n\u003ch3 data-start=\"2737\" data-end=\"2777\"\u003eCompatibility \u0026 system integration\u003c\/h3\u003e\n\u003cp data-start=\"2778\" data-end=\"3050\"\u003eOperation is \u003cstrong data-start=\"2794\" data-end=\"2852\"\u003eonly permitted in conjunction with a buffer tank ≥ 800 liters\u003c\/strong\u003e . For safe operation, a \u003cstrong data-start=\"2897\" data-end=\"2938\"\u003ereturn temperature increase to at least 55 °C\u003c\/strong\u003e is required. The boiler can be operated with various controllers (e.g., ecoMAX, Vera Bord, IE-72v5).\u003c\/p\u003e\n\u003chr data-start=\"3052\" data-end=\"3055\"\u003e\n\u003ch2 data-start=\"3057\" data-end=\"3078\"\u003eTechnical data\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3080\" data-end=\"3976\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3080\" data-end=\"3098\"\u003e\n\u003ctr data-start=\"3080\" data-end=\"3098\"\u003e\n\u003cth data-start=\"3080\" data-end=\"3090\" data-col-size=\"sm\" class=\"\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"3090\" data-end=\"3098\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3116\" data-end=\"3976\"\u003e\n\u003ctr data-start=\"3116\" data-end=\"3158\"\u003e\n\u003ctd data-start=\"3116\" data-end=\"3129\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3129\" data-end=\"3158\"\u003eMPM Projekt Marcin Nykiel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3159\" data-end=\"3184\"\u003e\n\u003ctd data-start=\"3159\" data-end=\"3168\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3168\" data-end=\"3184\"\u003eCaldo S-I 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3185\" data-end=\"3220\"\u003e\n\u003ctd data-start=\"3185\" data-end=\"3198\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3198\" data-end=\"3220\"\u003eWood gasification boiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3221\" data-end=\"3250\"\u003e\n\u003ctd data-start=\"3221\" data-end=\"3241\" data-col-size=\"sm\"\u003eNominal heat output\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3241\" data-end=\"3250\"\u003e18 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3251\" data-end=\"3283\"\u003e\n\u003ctd data-start=\"3251\" data-end=\"3272\" data-col-size=\"sm\"\u003eGenerated useful heat\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3272\" data-end=\"3283\"\u003e18.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3284\" data-end=\"3326\"\u003e\n\u003ctd data-start=\"3284\" data-end=\"3316\" data-col-size=\"sm\"\u003eEfficiency at nominal output\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3316\" data-end=\"3326\"\u003e83.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3327\" data-end=\"3364\"\u003e\n\u003ctd data-start=\"3327\" data-end=\"3356\" data-col-size=\"sm\"\u003eSeasonal energy efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3356\" data-end=\"3364\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3365\" data-end=\"3396\"\u003e\n\u003ctd data-start=\"3365\" data-end=\"3390\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3390\" data-end=\"3396\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3397\" data-end=\"3434\"\u003e\n\u003ctd data-start=\"3397\" data-end=\"3427\" data-col-size=\"sm\"\u003eEnergy efficiency index (EEI)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3427\" data-end=\"3434\"\u003e117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3435\" data-end=\"3489\"\u003e\n\u003ctd data-start=\"3435\" data-end=\"3448\" data-col-size=\"sm\"\u003eFuel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3448\" data-end=\"3489\"\u003eLog wood (hardwood, moisture ≤ 25%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3490\" data-end=\"3534\"\u003e\n\u003ctd data-start=\"3490\" data-end=\"3505\" data-col-size=\"sm\"\u003eBoiler class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3505\" data-end=\"3534\"\u003e5 (PN-EN 303-5 + A1:2023)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3535\" data-end=\"3584\"\u003e\n\u003ctd data-start=\"3535\" data-end=\"3571\" data-col-size=\"sm\"\u003eRecommended buffer tank volume\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3571\" data-end=\"3584\"\u003e800 liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3585\" data-end=\"3620\"\u003e\n\u003ctd data-start=\"3585\" data-end=\"3611\" data-col-size=\"sm\"\u003eMax. operating temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3611\" data-end=\"3620\"\u003e90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3621\" data-end=\"3659\"\u003e\n\u003ctd data-start=\"3621\" data-end=\"3650\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3650\" data-end=\"3659\"\u003e55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3660\" data-end=\"3690\"\u003e\n\u003ctd data-start=\"3660\" data-end=\"3681\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3681\" data-end=\"3690\"\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3691\" data-end=\"3740\"\u003e\n\u003ctd data-start=\"3691\" data-end=\"3726\" data-col-size=\"sm\"\u003eFlue gas temperature at nominal output\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3726\" data-end=\"3740\"\u003eapprox. 130 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3741\" data-end=\"3775\"\u003e\n\u003ctd data-start=\"3741\" data-end=\"3763\" data-col-size=\"sm\"\u003eBoiler water volume\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3763\" data-end=\"3775\"\u003e85 liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3776\" data-end=\"3800\"\u003e\n\u003ctd data-start=\"3776\" data-end=\"3786\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3786\" data-end=\"3800\"\u003eapprox. 450 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3801\" data-end=\"3834\"\u003e\n\u003ctd data-start=\"3801\" data-end=\"3826\" data-col-size=\"sm\"\u003eFlow\/return connection\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3826\" data-end=\"3834\"\u003e6\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3835\" data-end=\"3870\"\u003e\n\u003ctd data-start=\"3835\" data-end=\"3853\" data-col-size=\"sm\"\u003ePower supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3853\" data-end=\"3870\"\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3871\" data-end=\"3920\"\u003e\n\u003ctd data-start=\"3871\" data-end=\"3903\" data-col-size=\"sm\"\u003eElectrical power consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3903\" data-end=\"3920\"\u003emax. 0.023 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3921\" data-end=\"3976\"\u003e\n\u003ctd data-start=\"3921\" data-end=\"3944\" data-col-size=\"sm\"\u003eStandards \u0026 directives\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3944\" data-end=\"3976\"\u003eCE, Ecodesign (EU) 2015\/1189\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3978\" data-end=\"3981\"\u003e\n\u003ch2 data-start=\"3983\" data-end=\"4000\"\u003eScope of delivery\u003c\/h2\u003e\n\u003cul data-start=\"4002\" data-end=\"4090\"\u003e\n\u003cli data-start=\"4002\" data-end=\"4045\"\u003e\n\u003cp data-start=\"4004\" data-end=\"4045\"\u003eWood gasification boiler \u003cstrong data-start=\"4023\" data-end=\"4043\"\u003eMPM Caldo S-I 18\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4046\" data-end=\"4069\"\u003e\n\u003cp data-start=\"4048\" data-end=\"4069\"\u003eOperating instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4070\" data-end=\"4090\"\u003e\n\u003cp data-start=\"4072\" data-end=\"4090\"\u003eInstallation instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4092\" data-end=\"4095\"\u003e\n\u003ch2 data-start=\"4097\" data-end=\"4122\"\u003eAccessories \/ recommendation\u003c\/h2\u003e\n\u003cp data-start=\"4124\" data-end=\"4188\"\u003eFor standard-compliant and efficient operation, we recommend:\u003c\/p\u003e\n\u003cul data-start=\"4190\" data-end=\"4389\"\u003e\n\u003cli data-start=\"4190\" data-end=\"4224\"\u003e\n\u003cp data-start=\"4192\" data-end=\"4224\"\u003e\u003cstrong data-start=\"4192\" data-end=\"4222\"\u003eBuffer tank ≥ 800 liters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4225\" data-end=\"4264\"\u003e\n\u003cp data-start=\"4227\" data-end=\"4264\"\u003e\u003cstrong data-start=\"4227\" data-end=\"4262\"\u003eReturn temperature boosting group (55 °C)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4265\" data-end=\"4313\"\u003e\n\u003cp data-start=\"4267\" data-end=\"4313\"\u003e\u003cstrong data-start=\"4267\" data-end=\"4311\"\u003eThermal drain safety device (BVTS valve)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4314\" data-end=\"4347\"\u003e\n\u003cp data-start=\"4316\" data-end=\"4347\"\u003e\u003cstrong data-start=\"4316\" data-end=\"4345\"\u003eHeating control \u0026 sensors\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4348\" data-end=\"4389\"\u003e\n\u003cp data-start=\"4350\" data-end=\"4389\"\u003e\u003cstrong data-start=\"4350\" data-end=\"4387\"\u003eSafety group \u0026 connection sets\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4391\" data-end=\"4522\"\u003eYou will find suitable components in the categories \u003cem data-start=\"4441\" data-end=\"4457\"\u003eBuffer tanks\u003c\/em\u003e, \u003cem data-start=\"4459\" data-end=\"4479\"\u003eSafety groups\u003c\/em\u003e and \u003cem data-start=\"4484\" data-end=\"4501\"\u003eHeating accessories\u003c\/em\u003e on \u003cstrong data-start=\"4506\" data-end=\"4521\"\u003egemashop.de\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4524\" data-end=\"4527\"\u003e\n\u003ch2 data-start=\"4529\" data-end=\"4564\"\u003eInstallation \u0026 safety instructions\u003c\/h2\u003e\n\u003cp data-start=\"4566\" data-end=\"4906\"\u003eThe \u003cstrong data-start=\"4570\" data-end=\"4664\"\u003einstallation and commissioning may only be carried out by a qualified specialist company\u003c\/strong\u003e .\u003cbr data-start=\"4674\" data-end=\"4677\"\u003eOperation is \u003cstrong data-start=\"4693\" data-end=\"4719\"\u003eonly permitted with a buffer tank\u003c\/strong\u003e . A return temperature below 55 °C leads to corrosion and to \u003cstrong data-start=\"4793\" data-end=\"4817\"\u003eloss of warranty\u003c\/strong\u003e. Only fuels approved by the manufacturer may be used.\u003c\/p\u003e\n\u003chr data-start=\"4908\" data-end=\"4911\"\u003e\n\u003ch2 data-start=\"4913\" data-end=\"4921\"\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"4923\" data-end=\"5046\"\u003e\u003cstrong data-start=\"4923\" data-end=\"4962\"\u003e1. Which fuel is permitted?\u003c\/strong\u003e\u003cbr data-start=\"4962\" data-end=\"4965\"\u003eOnly split logs (hardwood) with a residual moisture content of ≤ 25 % are permitted.\u003c\/p\u003e\n\u003cp data-start=\"5048\" data-end=\"5173\"\u003e\u003cstrong data-start=\"5048\" data-end=\"5086\"\u003e2. Is a buffer tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"5086\" data-end=\"5089\"\u003eYes, operation is only permitted with a buffer tank of at least 800 liters.\u003c\/p\u003e\n\u003cp data-start=\"5175\" data-end=\"5308\"\u003e\u003cstrong data-start=\"5175\" data-end=\"5226\"\u003e3. Does the boiler comply with the Ecodesign Directive?\u003c\/strong\u003e\u003cbr data-start=\"5226\" data-end=\"5229\"\u003eYes, the MPM Caldo S-I 18 meets the requirements of EU Regulation 2015\/1189.\u003c\/p\u003e\n\u003cp data-start=\"5310\" data-end=\"5450\"\u003e\u003cstrong data-start=\"5310\" data-end=\"5360\"\u003e4. For which buildings is the boiler suitable?\u003c\/strong\u003e\u003cbr data-start=\"5360\" data-end=\"5363\"\u003eFor single-family houses, smaller multi-family houses, as well as commercial and workshop buildings.\u003c\/p\u003e\n\u003cp data-start=\"5452\" data-end=\"5590\"\u003e\u003cstrong data-start=\"5452\" data-end=\"5522\"\u003e5. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"5522\" data-end=\"5525\"\u003eYes, provided the safety requirements according to the standard are met.\u003c\/p\u003e\n\u003cp data-start=\"5592\" data-end=\"5710\"\u003e\u003cstrong data-start=\"5592\" data-end=\"5644\"\u003e6. What energy efficiency class does the boiler have?\u003c\/strong\u003e\u003cbr data-start=\"5644\" data-end=\"5647\"\u003eThe boiler is classified in energy efficiency class \u003cstrong data-start=\"5692\" data-end=\"5698\"\u003eA+\u003c\/strong\u003e .\u003c\/p\u003e\n\u003chr data-start=\"5712\" data-end=\"5715\"\u003e\n\u003ch2 data-start=\"5717\" data-end=\"5727\"\u003eConclusion\u003c\/h2\u003e\n\u003cp data-start=\"5729\" data-end=\"5956\"\u003eThe \u003cstrong data-start=\"5733\" data-end=\"5753\"\u003eMPM Caldo S-I 18\u003c\/strong\u003e is a powerful, ecodesign-compliant wood gasification boiler for anyone who relies on \u003cstrong data-start=\"5837\" data-end=\"5898\"\u003eefficient and independent heat supply with split logs\u003c\/strong\u003e . Order now and sustainably reduce heating costs.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Vaiketitel","offer_id":56649406349660,"sku":"MPMC18","price":3880.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-caldo-s-i-25-kw-holzvergaserkessel-a-ecodesign-klasse-5-holzvergaserkessel-2033103.webp?v=1770944052","url":"https:\/\/ee.gemashop.de\/en\/products\/mpm-caldo-s-i-18-kw-puugasutuskatel","provider":"GEMA Shop","version":"1.0","type":"link"}