{"product_id":"mpm-wood-plus-18-holzvergaserkessel-18kw","title":"MPM Wood Plus 18 wood gasification boiler 18 kW A+","description":"\u003cp data-start=\"972\" data-end=\"1402\"\u003eThe \u003cstrong data-start=\"976\" data-end=\"996\"\u003eMPM Wood Plus 18\u003c\/strong\u003e is a modern wood gasification boiler with 18 kW rated output for heating single-family homes and smaller commercial units.\u003cbr data-start=\"1128\" data-end=\"1131\"\u003eThe log wood boiler meets the requirements of the \u003cstrong data-start=\"1182\" data-end=\"1221\"\u003eEcodesign Regulation (EU) 2015\/1189\u003c\/strong\u003e as well as Class 5 according to PN-EN 303-5 and achieves energy efficiency class A+.\u003cbr data-start=\"1297\" data-end=\"1300\"\u003eDesigned for operation with a buffer tank, it offers efficient and low-emission wood heating.\u003c\/p\u003e\n\u003chr data-start=\"1404\" data-end=\"1407\"\u003e\n\u003ch2 data-start=\"1409\" data-end=\"1433\"\u003eHighlights \/ Benefits\u003c\/h2\u003e\n\u003cp data-start=\"1435\" data-end=\"1795\"\u003e⭐ 18 kW rated output – ideal for single-family homes and smaller commercial properties\u003cbr data-start=\"1513\" data-end=\"1516\"\u003e⭐ Energy efficiency class A+ – EEI 119 for high seasonal efficiency\u003cbr data-start=\"1582\" data-end=\"1585\"\u003e⭐ Class 5 according to PN-EN 303-5 – low emissions and Ecodesign-compliant\u003cbr data-start=\"1656\" data-end=\"1659\"\u003e⭐ Wood gasification technology – high efficiency and clean combustion\u003cbr data-start=\"1731\" data-end=\"1734\"\u003e⭐ Suitable for open and closed systems (max. 1.5 bar)\u003c\/p\u003e\n\u003chr data-start=\"1797\" data-end=\"1800\"\u003e\n\u003ch1 data-start=\"1802\" data-end=\"1823\"\u003eProduct Description\u003c\/h1\u003e\n\u003ch2 data-start=\"1825\" data-end=\"1855\"\u003eApplication Area \u0026amp; Target Group\u003c\/h2\u003e\n\u003cp data-start=\"1857\" data-end=\"1939\"\u003eThe MPM Wood Plus 18 is a manually loaded wood gasification boiler for heating:\u003c\/p\u003e\n\u003cul data-start=\"1941\" data-end=\"2042\"\u003e\n\u003cli data-start=\"1941\" data-end=\"1963\"\u003e\n\u003cp data-start=\"1943\" data-end=\"1963\"\u003eSingle-family homes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1964\" data-end=\"1980\"\u003e\n\u003cp data-start=\"1966\" data-end=\"1980\"\u003eResidential buildings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1981\" data-end=\"2001\"\u003e\n\u003cp data-start=\"1983\" data-end=\"2001\"\u003eCommercial pavilions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2017\"\u003e\n\u003cp data-start=\"2004\" data-end=\"2017\"\u003eWorkshops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2018\" data-end=\"2042\"\u003e\n\u003cp data-start=\"2020\" data-end=\"2042\"\u003eCatering establishments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2044\" data-end=\"2214\"\u003eOperation is carried out with \u003cstrong data-start=\"2068\" data-end=\"2099\"\u003elog wood (moisture ≤ 25 %)\u003c\/strong\u003e. The boiler is intended exclusively for operation at rated output in conjunction with a buffer tank.\u003c\/p\u003e\n\u003chr data-start=\"2216\" data-end=\"2219\"\u003e\n\u003ch2 data-start=\"2221\" data-end=\"2242\"\u003eEveryday Benefits\u003c\/h2\u003e\n\u003cp data-start=\"2244\" data-end=\"2386\"\u003eThe gasification technology separates degassing and combustion into two chambers. This achieves particularly clean and efficient combustion.\u003c\/p\u003e\n\u003cp data-start=\"2388\" data-end=\"2639\"\u003eThe integrated ceramic burner with controlled primary and secondary air ensures stable flame guidance.\u003cbr data-start=\"2501\" data-end=\"2504\"\u003eThe large loading chamber (approx. 70 liters \/ approx. 25 kg of wood) enables comfortable refilling intervals with a burn time of up to 5 hours.\u003c\/p\u003e\n\u003chr data-start=\"2641\" data-end=\"2644\"\u003e\n\u003ch2 data-start=\"2646\" data-end=\"2670\"\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e\n\u003cp data-start=\"2672\" data-end=\"2750\"\u003eThe boiler is made of certified steel boiler plate and features:\u003c\/p\u003e\n\u003cul data-start=\"2752\" data-end=\"2970\"\u003e\n\u003cli data-start=\"2752\" data-end=\"2776\"\u003e\n\u003cp data-start=\"2754\" data-end=\"2776\"\u003eMetal-ceramic burner\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2777\" data-end=\"2828\"\u003e\n\u003cp data-start=\"2779\" data-end=\"2828\"\u003eVertical flue gas channels with turbulence unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2829\" data-end=\"2854\"\u003e\n\u003cp data-start=\"2831\" data-end=\"2854\"\u003eMechanical draft regulator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2855\" data-end=\"2911\"\u003e\n\u003cp data-start=\"2857\" data-end=\"2911\"\u003eConnection for thermostatic safety valve DBV-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2912\" data-end=\"2938\"\u003e\n\u003cp data-start=\"2914\" data-end=\"2938\"\u003e40 mm mineral wool insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2939\" data-end=\"2970\"\u003e\n\u003cp data-start=\"2941\" data-end=\"2970\"\u003eThermometer in the upper area\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2972\" data-end=\"3063\"\u003eThe maximum operating temperature is 90 °C, the maximum permissible operating pressure is 1.5 bar.\u003c\/p\u003e\n\u003chr data-start=\"3065\" data-end=\"3068\"\u003e\n\u003ch2 data-start=\"3070\" data-end=\"3091\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e\n\u003cp data-start=\"3093\" data-end=\"3231\"\u003eThe MPM Wood Plus 18 meets the requirements of the \u003cstrong data-start=\"3144\" data-end=\"3183\"\u003eEcodesign Regulation (EU) 2015\/1189\u003c\/strong\u003e and holds a valid certificate ED\/1202\/23.\u003c\/p\u003e\n\u003cp data-start=\"3233\" data-end=\"3341\"\u003eSeasonal space heating energy efficiency: 81 %\u003cbr data-start=\"3277\" data-end=\"3280\"\u003eEnergy efficiency index (EEI): 119\u003cbr data-start=\"3312\" data-end=\"3315\"\u003eEnergy efficiency class: A+\u003c\/p\u003e\n\u003cp data-start=\"3343\" data-end=\"3399\"\u003eEmissions at rated output (log wood ≤ 25 % moisture):\u003c\/p\u003e\n\u003cul data-start=\"3401\" data-end=\"3472\"\u003e\n\u003cli data-start=\"3401\" data-end=\"3417\"\u003e\n\u003cp data-start=\"3403\" data-end=\"3417\"\u003ePM: 15 mg\/m³\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3418\" data-end=\"3435\"\u003e\n\u003cp data-start=\"3420\" data-end=\"3435\"\u003eOGC: 19 mg\/m³\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3436\" data-end=\"3453\"\u003e\n\u003cp data-start=\"3438\" data-end=\"3453\"\u003eCO: 401 mg\/m³\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3454\" data-end=\"3472\"\u003e\n\u003cp data-start=\"3456\" data-end=\"3472\"\u003eNOx: 145 mg\/m³\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3474\" data-end=\"3477\"\u003e\n\u003ch2 data-start=\"3479\" data-end=\"3516\"\u003eCompatibility \u0026amp; System Integration\u003c\/h2\u003e\n\u003cp data-start=\"3518\" data-end=\"3545\"\u003eOperation is possible in:\u003c\/p\u003e\n\u003cul data-start=\"3547\" data-end=\"3672\"\u003e\n\u003cli data-start=\"3547\" data-end=\"3571\"\u003e\n\u003cp data-start=\"3549\" data-end=\"3571\"\u003eOpen heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3572\" data-end=\"3672\"\u003e\n\u003cp data-start=\"3574\" data-end=\"3672\"\u003eClosed heating systems with diaphragm expansion vessel, safety valve and overheating protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3674\" data-end=\"3860\"\u003eA \u003cstrong data-start=\"3678\" data-end=\"3730\"\u003ebuffer tank with a minimum volume of 800 liters\u003c\/strong\u003e is mandatory.\u003cbr data-start=\"3750\" data-end=\"3753\"\u003eThe return temperature must permanently be at least 55 °C to avoid low-temperature corrosion.\u003c\/p\u003e\n\u003cp data-start=\"3862\" data-end=\"3898\"\u003eRecommended chimney requirements:\u003c\/p\u003e\n\u003cul data-start=\"3900\" data-end=\"4014\"\u003e\n\u003cli data-start=\"3900\" data-end=\"3950\"\u003e\n\u003cp data-start=\"3902\" data-end=\"3950\"\u003eMinimum cross-section: 180 × 180 mm or Ø 178 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3951\" data-end=\"3971\"\u003e\n\u003cp data-start=\"3953\" data-end=\"3971\"\u003eMinimum height: 8 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3972\" data-end=\"4014\"\u003e\n\u003cp data-start=\"3974\" data-end=\"4014\"\u003eRequired draft: approx. 0.19–0.20 mbar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4016\" data-end=\"4019\"\u003e\n\u003ch1 data-start=\"4021\" data-end=\"4039\"\u003eTechnical Data\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4041\" data-end=\"5053\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4041\" data-end=\"4059\"\u003e\n\u003ctr data-start=\"4041\" data-end=\"4059\"\u003e\n\u003cth data-start=\"4041\" data-end=\"4051\" data-col-size=\"sm\" class=\"\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"4051\" data-end=\"4059\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4080\" data-end=\"5053\"\u003e\n\u003ctr data-start=\"4080\" data-end=\"4122\"\u003e\n\u003ctd data-start=\"4080\" data-end=\"4093\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"4093\" data-end=\"4122\" data-col-size=\"sm\"\u003eMPM Projekt Marcin Nykiel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4123\" data-end=\"4148\"\u003e\n\u003ctd data-start=\"4123\" data-end=\"4132\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"4132\" data-end=\"4148\" data-col-size=\"sm\"\u003eWood Plus 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4149\" data-end=\"4184\"\u003e\n\u003ctd data-start=\"4149\" data-end=\"4162\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e\n\u003ctd data-start=\"4162\" data-end=\"4184\" data-col-size=\"sm\"\u003eWood gasification boiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4185\" data-end=\"4209\"\u003e\n\u003ctd data-start=\"4185\" data-end=\"4200\" data-col-size=\"sm\"\u003eRated output\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4200\" data-end=\"4209\"\u003e18 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4210\" data-end=\"4241\"\u003e\n\u003ctd data-start=\"4210\" data-end=\"4235\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4235\" data-end=\"4241\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4242\" data-end=\"4279\"\u003e\n\u003ctd data-start=\"4242\" data-end=\"4272\" data-col-size=\"sm\"\u003eEnergy efficiency index (EEI)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4272\" data-end=\"4279\"\u003e119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4280\" data-end=\"4322\"\u003e\n\u003ctd data-start=\"4280\" data-end=\"4314\" data-col-size=\"sm\"\u003eSeasonal space heating efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4314\" data-end=\"4322\"\u003e81%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4323\" data-end=\"4372\"\u003e\n\u003ctd data-start=\"4323\" data-end=\"4338\" data-col-size=\"sm\"\u003eBoiler class\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4338\" data-end=\"4372\"\u003eClass 5 (PN-EN 303-5:2021-09)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4373\" data-end=\"4408\"\u003e\n\u003ctd data-start=\"4373\" data-end=\"4400\" data-col-size=\"sm\"\u003eThermal efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4400\" data-end=\"4408\"\u003e89%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4409\" data-end=\"4451\"\u003e\n\u003ctd data-start=\"4409\" data-end=\"4422\" data-col-size=\"sm\"\u003eFuel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4422\" data-end=\"4451\"\u003eLog wood ≤ 25% moisture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4452\" data-end=\"4487\"\u003e\n\u003ctd data-start=\"4452\" data-end=\"4473\" data-col-size=\"sm\"\u003eLoading chamber volume\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4473\" data-end=\"4487\"\u003eapprox. 70 dm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4488\" data-end=\"4519\"\u003e\n\u003ctd data-start=\"4488\" data-end=\"4506\" data-col-size=\"sm\"\u003eFuel quantity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4506\" data-end=\"4519\"\u003eapprox. 25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4520\" data-end=\"4544\"\u003e\n\u003ctd data-start=\"4520\" data-end=\"4533\" data-col-size=\"sm\"\u003eBurn time\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4533\" data-end=\"4544\"\u003eapprox. 5 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4545\" data-end=\"4579\"\u003e\n\u003ctd data-start=\"4545\" data-end=\"4567\" data-col-size=\"sm\"\u003eFuel consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4567\" data-end=\"4579\"\u003e5.5 kg\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4580\" data-end=\"4613\"\u003e\n\u003ctd data-start=\"4580\" data-end=\"4603\" data-col-size=\"sm\"\u003eBoiler water volume\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4603\" data-end=\"4613\"\u003e80 dm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4614\" data-end=\"4646\"\u003e\n\u003ctd data-start=\"4614\" data-end=\"4635\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4635\" data-end=\"4646\"\u003e1.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4647\" data-end=\"4680\"\u003e\n\u003ctd data-start=\"4647\" data-end=\"4668\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4668\" data-end=\"4680\"\u003e60–90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4681\" data-end=\"4720\"\u003e\n\u003ctd data-start=\"4681\" data-end=\"4711\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4711\" data-end=\"4720\"\u003e55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4721\" data-end=\"4753\"\u003e\n\u003ctd data-start=\"4721\" data-end=\"4739\" data-col-size=\"sm\"\u003eFlue gas temperature\u003c\/td\u003e\n\u003ctd data-start=\"4739\" data-end=\"4753\" data-col-size=\"sm\"\u003e125–140 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4754\" data-end=\"4785\"\u003e\n\u003ctd data-start=\"4754\" data-end=\"4773\" data-col-size=\"sm\"\u003eFlue gas mass flow\u003c\/td\u003e\n\u003ctd data-start=\"4773\" data-end=\"4785\" data-col-size=\"sm\"\u003e10.8 g\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4786\" data-end=\"4804\"\u003e\n\u003ctd data-start=\"4786\" data-end=\"4793\" data-col-size=\"sm\"\u003eHeight\u003c\/td\u003e\n\u003ctd data-start=\"4793\" data-end=\"4804\" data-col-size=\"sm\"\u003e1050 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4805\" data-end=\"4830\"\u003e\n\u003ctd data-start=\"4805\" data-end=\"4820\" data-col-size=\"sm\"\u003eOverall width\u003c\/td\u003e\n\u003ctd data-start=\"4820\" data-end=\"4830\" data-col-size=\"sm\"\u003e640 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4831\" data-end=\"4858\"\u003e\n\u003ctd data-start=\"4831\" data-end=\"4848\" data-col-size=\"sm\"\u003eCasing width\u003c\/td\u003e\n\u003ctd data-start=\"4848\" data-end=\"4858\" data-col-size=\"sm\"\u003e550 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4859\" data-end=\"4884\"\u003e\n\u003ctd data-start=\"4859\" data-end=\"4873\" data-col-size=\"sm\"\u003eOverall length\u003c\/td\u003e\n\u003ctd data-start=\"4873\" data-end=\"4884\" data-col-size=\"sm\"\u003e1070 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4885\" data-end=\"4920\"\u003e\n\u003ctd data-start=\"4885\" data-end=\"4910\" data-col-size=\"sm\"\u003eLength without chimney\u003c\/td\u003e\n\u003ctd data-start=\"4910\" data-end=\"4920\" data-col-size=\"sm\"\u003e870 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4921\" data-end=\"4945\"\u003e\n\u003ctd data-start=\"4921\" data-end=\"4931\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4931\" data-end=\"4945\" data-col-size=\"sm\"\u003eapprox. 370 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4946\" data-end=\"4980\"\u003e\n\u003ctd data-start=\"4946\" data-end=\"4971\" data-col-size=\"sm\"\u003eFlow\/return connection\u003c\/td\u003e\n\u003ctd data-start=\"4971\" data-end=\"4980\" data-col-size=\"sm\"\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4981\" data-end=\"5022\"\u003e\n\u003ctd data-start=\"4981\" data-end=\"5009\" data-col-size=\"sm\"\u003eRecommended buffer volume\u003c\/td\u003e\n\u003ctd data-start=\"5009\" data-end=\"5022\" data-col-size=\"sm\"\u003e800 liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5023\" data-end=\"5053\"\u003e\n\u003ctd data-start=\"5023\" data-end=\"5042\" data-col-size=\"sm\"\u003eCE marking\u003c\/td\u003e\n\u003ctd data-start=\"5042\" data-end=\"5053\" data-col-size=\"sm\"\u003eCE 2023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"5055\" data-end=\"5058\"\u003e\n\u003ch2 data-start=\"5060\" data-end=\"5075\"\u003eScope of delivery\u003c\/h2\u003e\n\u003cul data-start=\"5077\" data-end=\"5153\"\u003e\n\u003cli data-start=\"5077\" data-end=\"5108\"\u003e\n\u003cp data-start=\"5079\" data-end=\"5108\"\u003eMPM Wood Plus 18 heating boiler\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5109\" data-end=\"5132\"\u003e\n\u003cp data-start=\"5111\" data-end=\"5132\"\u003eOperating instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5133\" data-end=\"5153\"\u003e\n\u003cp data-start=\"5135\" data-end=\"5153\"\u003eInstallation instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5155\" data-end=\"5158\"\u003e\n\u003ch2 data-start=\"5160\" data-end=\"5199\"\u003eAccessories \/ Recommendation (cross-selling)\u003c\/h2\u003e\n\u003cp data-start=\"5201\" data-end=\"5241\"\u003eFor optimal operation, we recommend:\u003c\/p\u003e\n\u003cul data-start=\"5243\" data-end=\"5434\"\u003e\n\u003cli data-start=\"5243\" data-end=\"5274\"\u003e\n\u003cp data-start=\"5245\" data-end=\"5274\"\u003eBuffer tank from 800 liters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5275\" data-end=\"5321\"\u003e\n\u003cp data-start=\"5277\" data-end=\"5321\"\u003eThermostatic anti-condensation valve 55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5322\" data-end=\"5351\"\u003e\n\u003cp data-start=\"5324\" data-end=\"5351\"\u003eSafety valve \/ DBV-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5352\" data-end=\"5377\"\u003e\n\u003cp data-start=\"5354\" data-end=\"5377\"\u003eFour-way mixing valve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5378\" data-end=\"5406\"\u003e\n\u003cp data-start=\"5380\" data-end=\"5406\"\u003eChimney draft regulator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5407\" data-end=\"5434\"\u003e\n\u003cp data-start=\"5409\" data-end=\"5434\"\u003eReturn temperature boosting system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5436\" data-end=\"5517\"\u003eSuitable components can be found in the Wood Heating \u0026 Accessories section on gemashop.de.\u003c\/p\u003e\n\u003chr data-start=\"5519\" data-end=\"5522\"\u003e\n\u003ch2 data-start=\"5524\" data-end=\"5557\"\u003eInstallation \u0026 safety instructions\u003c\/h2\u003e\n\u003cp data-start=\"5559\" data-end=\"5656\"\u003eInstallation and commissioning must only be carried out by qualified specialist personnel.\u003c\/p\u003e\n\u003cp data-start=\"5658\" data-end=\"5829\"\u003eThe boiler may only be operated with suitable log wood.\u003cbr data-start=\"5721\" data-end=\"5724\"\u003ePermanent failure to maintain a return temperature of 55 °C leads to corrosion and loss of warranty.\u003c\/p\u003e\n\u003cp data-start=\"5831\" data-end=\"5903\"\u003eThe safety distance to combustible materials is at least 1 m.\u003c\/p\u003e\n\u003chr data-start=\"5905\" data-end=\"5908\"\u003e\n\u003ch1 data-start=\"5910\" data-end=\"5915\"\u003eFAQ\u003c\/h1\u003e\n\u003cp data-start=\"5917\" data-end=\"6031\"\u003e\u003cstrong data-start=\"5917\" data-end=\"5961\"\u003e1. What type of wood may be used?\u003c\/strong\u003e\u003cbr data-start=\"5961\" data-end=\"5964\"\u003eLog wood (hardwood) with a maximum moisture content of 25%, ideally 12–20%.\u003c\/p\u003e\n\u003cp data-start=\"6033\" data-end=\"6133\"\u003e\u003cstrong data-start=\"6033\" data-end=\"6071\"\u003e2. Is a buffer tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"6071\" data-end=\"6074\"\u003eYes, a minimum buffer volume of 800 liters is required.\u003c\/p\u003e\n\u003cp data-start=\"6135\" data-end=\"6282\"\u003e\u003cstrong data-start=\"6135\" data-end=\"6205\"\u003e3. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"6205\" data-end=\"6208\"\u003eYes, with a safety valve, diaphragm expansion vessel, and overheating protection.\u003c\/p\u003e\n\u003cp data-start=\"6284\" data-end=\"6374\"\u003e\u003cstrong data-start=\"6284\" data-end=\"6333\"\u003e4. What efficiency class does the boiler have?\u003c\/strong\u003e\u003cbr data-start=\"6333\" data-end=\"6336\"\u003eEnergy efficiency class A+ with EEI 119.\u003c\/p\u003e\n\u003cp data-start=\"6376\" data-end=\"6486\"\u003e\u003cstrong data-start=\"6376\" data-end=\"6425\"\u003e5. What emission class does the boiler meet?\u003c\/strong\u003e\u003cbr data-start=\"6425\" data-end=\"6428\"\u003eClass 5 according to PN-EN 303-5:2021-09 and Ecodesign 2015\/1189.\u003c\/p\u003e\n\u003cp data-start=\"6488\" data-end=\"6546\"\u003e\u003cstrong data-start=\"6488\" data-end=\"6535\"\u003e6. What is the maximum operating pressure?\u003c\/strong\u003e\u003cbr data-start=\"6535\" data-end=\"6538\"\u003e1.5 bar.\u003c\/p\u003e\n\u003cp data-start=\"6548\" data-end=\"6670\"\u003e\u003cstrong data-start=\"6548\" data-end=\"6605\"\u003e7. What minimum return temperature must be maintained?\u003c\/strong\u003e\u003cbr data-start=\"6605\" data-end=\"6608\"\u003eAt least 55 °C to avoid low-temperature corrosion.\u003c\/p\u003e\n\u003chr data-start=\"6672\" data-end=\"6675\"\u003e\n\u003ch2 data-start=\"6677\" data-end=\"6685\"\u003eConclusion\u003c\/h2\u003e\n\u003cp data-start=\"6687\" data-end=\"6900\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe MPM Wood Plus 18 is a powerful, Ecodesign-compliant wood gasification boiler with high efficiency and low emissions.\u003cbr data-start=\"6818\" data-end=\"6821\"\u003eA reliable solution for modern log wood heating systems with buffer tank.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Vaiketitel","offer_id":54128521478492,"sku":"MPMWP18","price":2836.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-18-kw-holzvergaserkessel-a-klasse-5-o178-8766655.webp?v=1770692476","url":"https:\/\/ee.gemashop.de\/en\/products\/mpm-wood-plus-18-puugaasistuskatel-18-kw","provider":"GEMA Shop","version":"1.0","type":"link"}